+ | ====== Panel Description - Fanning ====== | ||
+ | \\ | ||
+ | Fanning is as an oriental ribbon fan spreading out the beams for more fixtures.\\ | ||
+ | \\ | ||
+ | {{: | ||
+ | \\ | ||
+ | This means that the buttons in this part of the movement panel only have effect when more fixtures are selected and not on one alone.\\ | ||
+ | \\ | ||
+ | {{: | ||
+ | \\ | ||
+ | When more fixtures are placed next to each other the beams may be one big spot because all beams are parallel.\\ | ||
+ | By using fanning it is possible to spread out the beams as shown bellow.\\ | ||
+ | \\ | ||
+ | \\ | ||
+ | Parallel beams.\\ | ||
+ | {{: | ||
+ | \\ | ||
+ | \\ | ||
+ | Spread beams\\ | ||
+ | {{: | ||
+ | \\ | ||
+ | Here the settings is “First” = -10% (First is defined as left Fixture), “Last” = 10% (Last is defined as right fixture), “Pan Fan” or “Set Fan”\\ | ||
+ | \\ | ||
+ | \\ | ||
+ | {{: | ||
+ | \\ | ||
+ | The same can be done with the Tilt.\\ | ||
+ | \\ | ||
+ | \\ | ||
+ | \\ | ||
+ | Additional center of the fan can be moved with the “Center” slider.\\ | ||
+ | By adjusting the center of the fan then the spread is different from one side to an other.\\ | ||
+ | \\ | ||
+ | \\ | ||
+ | {{: | ||
+ | \\ | ||
+ | Here the settings are “First” = -15%, “Last” = 5% and “Center” = -5%.\\ | ||
+ | The spread will then be -15, -10, -5, 0 and 5%\\ | ||
+ | \\ | ||
+ | \\ | ||
+ | \\ | ||
+ | **Center Offset.**\\ | ||
+ | The parameters above is related to the beams pointing direction and in the figures the fixture is placed with the same spacing.\\ | ||
+ | If the fixture is placed with unequal distance then “Center Offset” are to be used.\\ | ||
+ | Center “Offset” may be a inproper word because when the Center fixture is exactly in the middle the offset is 50% meaning that it is actually describing the Center fixture placement.\\ | ||
+ | Bellow are two example with Center offset. The optimal use are to be tested in practice.\\ | ||
+ | \\ | ||
+ | \\ | ||
+ | {{: | ||
+ | \\ | ||
+ | In this figure the “Center Offset” is 25% meaning that fixture no. 2 from left is center.\\ | ||
+ | \\ | ||
+ | The left fixture is 0 and the right fixture is 100%\\ | ||
+ | In this figure the distance between the fixtures is 1,1,2,1. The total distance is therefore 4.\\ | ||
+ | So the fixture is placed in the following distance.\\ | ||
+ | Fixture 1: 0%\\ | ||
+ | Fixture 2, Center: (100/4)*1 = 25%\\ | ||
+ | Fixture 3: (100/ | ||
+ | Fixture 4: (100/ | ||
+ | Fixture 5: 100%\\ | ||
+ | \\ | ||
+ | And the First = -10%, Last = 10% and Center = 0%\\ | ||
+ | \\ | ||
+ | \\ | ||
+ | \\ | ||
+ | {{: | ||
+ | \\ | ||
+ | In this figure the “Center Offset” is 40%. Here fixture no. 3 from left is the center but there is a spacing between the center fixture and the next.\\ | ||
+ | \\ | ||
+ | The left fixture is 0 and the right fixture is 100%\\ | ||
+ | In this figure the distance between the fixtures is 1,1,2,1. The total distance is therefore 5.\\ | ||
+ | So the fixture is placed in the following distance.\\ | ||
+ | Fixture 1: 0%\\ | ||
+ | Fixture 2: (100/5)*1 = 20%\\ | ||
+ | Fixture 3, center: (100/ | ||
+ | Fixture 4: (100/ | ||
+ | Fixture 5: 100%\\ | ||
+ | \\ | ||
+ | And the First = -10%, Last = 10% and Center = 0%\\ | ||
+ | \\ | ||
+ | \\ | ||
+ | \\ | ||
+ | \\ | ||
+ | **Note: | ||
+ | To get the optimum performance it is important to set this offset else the beams will not track when they are moved to the outer values.\\ | ||
+ | \\ | ||
+ | \\ | ||
+ | \\ | ||
+ | **Additional Fan control.**\\ | ||
+ | The whole fan can additional be moved with the arrow control. This will not increase / decrease the fan size but just move whole fan in the arrow direction. \\ | ||
+ | \\ | ||
+ | By pressing the “Center” icon in the arrow matrix or the XYcoordinate the fanning is reset.\\ | ||
+ | \\ | ||
+ | \\ | ||
+ | ---- | ||
+ | \\ |
fixture_control/fanning_panel.txt · Last modified: 2013/03/11 03:45 by 127.0.0.1